MIL-S-45921A(AR)
visible at the bottom of the insufficiently filled joint area. Any
repairs which are made to the coating or the adhesive joint area
and the method of repairing shall have the prior approval of the
technical agency.
Stock assemblies shall be capable of
3.2.4 Twist.
withstanding a torque of 40 pound-feet without evidence of cracks
or breakage when tested as specified in 4.5.3.3.2 and 4.6.2.
3.2.5 Shock resistance. When assembled as a component of
the M14 rifle, stock assemblies shall be capable of passing the
shock resistance test (grenade firing) specified in 4.5.3.3.3 and
4.6.3 without evidence of cracks or breakage.
3.2.6 Functioning firing. When assembled as a component of
the M14 rifle, stock assemblies shall be capable of passing the
functioning test specified in 4.6.4 without-malfunction or breakage
attributable to the stock assembly without butt plate.
3.2.7 Tarqeting and accuracy. When the stock assembly is
assembled as a component of the M14 rifle, the targeting and
accuracy of the plastic stock shall be equal to or better than
the targeting and accuracy of the wooden stock subassembly when
assembled as a component of the M14 rifle, and in compliance with
the targeting and accuracy requirements of MIL-R-45012.
3.2.8 Shock resistance endurance. When assembled as a
component of the M14 rifle, stock assemblies shall be capable of
passing the 100 round grenade shock resistance endurance test
specified in 4.6.6 without evidence of cracks or breakage.
3.2.9 Low temperature shock resistance. When assembled as a
component of the M14 rifle, stock assemblies shall be capable of
passing the low temperature shock resistance test (grenade firing)
specified in 4.6.7 without evidence of cracks or breakage.
3.2.10 Low temperature abuse. When assembled as a
component of the M14 rifle, stock assemblies shall be capable of
passing the low temperature abuse test specified in 4.6.8 without
evidence of cracks or breakage.
3.2.11 Heat resistance. When assembled as a component of
the M14 rifle, stock assemblies shall be capable of passing the
heat resistance test specified in 4.6.9 without injurious charring
or injurious volatilization.